Manuals and User Guides for Bryant PLUS 95S Gas Furnace. We have 3 Bryant PLUS 95S Gas Furnace manuals available for free PDF download: Installation Instructions Manual, Product Data, Owner's Manual
Bryant PLUS 95S Installation Instructions Manual (63 pages)
SERIES A DIRECT-VENT 4-WAY MULTIPOISE CONDENSING GAS FURNACE WITH PERFECT SENSE PERFECT HUMIDITY
Brand:Bryant | Category:Furnace | Size:4.2 MB
Table of Contents
-
Installation Instructions
1
-
Important Information
2
-
Table of Contents
3
-
Safety Considerations
3
-
Dimensional Drawing
4
-
Installer Packet Contents
5
-
Loose Parts Bag Contents
5
-
Installation
6
-
Minimum Inches Clearance to Combustible Construction
6
-
Combustion
7
-
-
Codes and Standards
7
-
Electrostatic Discharge (Esd) Precautions
7
-
Introduction
7
-
Upflow Application
8
-
Condensate Trap Tubing
8
-
-
Applications
8
-
Condensate Trap (Alternate Upflow Orientation)
9
-
Upper Inducer Housing Drain Connection
10
-
Upper Collector Box Drain Connection
10
-
Pressure Switch Tubing
10
-
Trap Location
10
-
Downflow Applications
11
-
Condensate Trap Location
11
-
Horizontal Left (Supply - Air Discharge) Applications
12
-
Horizontal Left Tube Configuration
12
-
Attic Location and Working Platform
13
-
Construct a Working Platform
14
-
Horizontal Right (Supply - Air Discharge) Applications
15
-
Carbon Monoxide Poisoning Hazard
15
-
-
Location
16
-
Furnace Location Relative to Cooling Equipment
17
-
Hazardous Locations
17
-
Installation in Horizontal Applications
18
-
Installation in Upflow or Downflow Applications
18
-
Leveling Legs
18
-
Duct Flanges Diagram
19
-
Furnace, Plenum, and Coil Assembly or Coil Box Diagram
19
-
Furnace, Plenum, and Subbase Installed on a Combustible Floor
19
-
Crawlspace Horizontal Application for Direct Vent
20
-
Air Ducts
21
-
Ductwork Acoustical Treatment
21
-
Opening Dimensions
21
-
Supply Air Connections
21
-
Filter Arrangement
22
-
Return Air Connections
22
-
Bottom Closure Panel
23
-
Gas Piping
23
-
Casing Pipe Grommets
24
-
Removing Bottom Closure Panel
24
-
Typical Gas Pipe Arrangement
24
-
115V Wiring
25
-
Electrical Connections
25
-
Maximum Capacity of Pipe
25
-
Disconnect Switch and Furnace
26
-
Electrical Data
26
-
Heating and Cooling Application Wiring Diagram
26
-
24V Wiring
27
-
Electronic Air Cleaner (Eac)/Humidifier (HUM)
27
-
J-Box Relocation
27
-
Removal of Existing Furnaces from Common Vent Systems
27
-
-
Air for Combustion and Ventilation
28
-
Combustion - Air and Vent Pipe Systems
28
-
Direct Vent / 2-Pipe System
28
-
Ventilated Combustion Air Option Materials
28
-
Approved Combustion-Air and Vent Pipe, Fitting and Cement Materials
29
-
Combustion-Air and Vent Pipe Diameter
29
-
Installation Guidelines for Combustion Air Pipe and Vent Pipe
29
-
Furnace Control
30
-
Direct Vent Termination Clearance
31
-
Ventilated Combustion Air Vent Termination Clearance
32
-
Combustion Air and Vent Termination for Direct Vent (2-Pipe) System
33
-
Vent Pipe Termination for Ventilated Combustion Air System
33
-
Combustion Air and Vent Pipe Connections
34
-
Combustion Air and Vent Pipe Transition Location/Elbow Configuration
34
-
Combustion Air Pipe Attachment
34
-
Attachment of Combustion Air Intake Housing Plug Fitting
35
-
Combustion Air Termination - Ventilated Combustion Air Option
35
-
Intake Housing Plug Fitting Drain
35
-
Combustion Air Termination - Direct Vent / 2-Pipe System
36
-
-
Vent Pipe
36
-
Attic Termination
37
-
Crawlspace Termination
37
-
Short Vent (5 to 8 Ft. / 1.5M to 2.4M) System
38
-
Concentric Vent / Combustion Air Termination Kit/2-Pipe System Only
39
-
Extended Exposed Sidewall Pipes
39
-
Two-Pipe Termination Kit (Direct Vent/2-Pipe System
39
-
-
Vent Termination
39
-
Maximum Allowable Exposed Vent Pipe Length with Insulation
40
-
Maximum Allowable Pipe Length
41
-
-
Condensate Drain
43
-
Multi-Venting and Vent Terminations
43
-
Vent Termination Kit for Direct Vent/2-Pipe System
43
-
Air Conditioning (A/C) Setup Switches
44
-
Continuous Fan (CF) Setup Switches
44
-
Setup Switches
44
-
-
- Start- -Up, Adjustments, and Safety Check
44
-
Prime Condensate Trap with Water
45
-
Wiring Diagram
46
-
Inducer Housing Drain Tube
47
-
Filling Condensate Trap
47
-
Furnace Setup Switch Description
47
-
Purge Gas Lines
48
-
Single-Stage Thermostat and Step-Modulating Heating
48
-
Two-Stage Thermostat and Two-Stage Low / High Heating
49
-
Two-Stage Thermostat and Two-Stage Medium/High Heating
49
-
Switching from Low- to High-Heat
49
-
Switching from Medium- to High-Heat
49
-
Cooling Mode
50
-
Thermidistat Mode
50
-
Component Test
51
-
Heat Pump
51
-
Continuous Blower Speed Selection from Thermostat
51
-
Super Dehumidify Mode/Continuous Blower Mode
51
-
Adjustments
54
-
Set Gas Input Rate
54
-
Redundant Automatic Gas Valve
54
-
Burner Orifice
55
-
Orifice Size and Manifold Pressures for Gas Input Rate
56
-
Altitude Derate Multiplier for USA
58
-
Burner Flame
58
-
Set Temperature Rise
59
-
Set Thermostat Heat Anticipator
59
-
Gas Rate Cu Ft/Hr
59
-
Check Safety Controls
60
-
Check Primary Limit Control
60
-
Check Pressure Switches
60
-
-
Checklist
60
Advertisem*nt
Bryant PLUS 95S Product Data (21 pages)
100 Series DELUXE 4-WAY MULTIPOISE VARIABLE-SPEED MULTI-STAGE CONDENSING Input Rates: 60,000 thru 120,000 Btuh
Brand:Bryant | Category:Furnace | Size:1.63 MB
Table of Contents
- Furnace Components
3
- Physical Data
8
- Performance Data
8
- Operating Mode
9
-
Condensate Trap
11
- Electrical Data
14
-
Typical Wiring Schematic
14
-
Clearance to Combustibles
17
-
Typical Installations
18
-
Guide Specifications
20
-
Operating Characteristics
20
-
Electrical Requirements
20
Bryant PLUS 95S Owner's Manual (14 pages)
DIRECT VENT 4-WAY MULTIPOISE MODULATING CONDENSING GAS FURNACE WITH PERFECT SENSE PERFECT HUMIDITY
Brand:Bryant | Category:Furnace | Size:0.61 MB
Table of Contents
-
Table of Contents
2
-
Welcome to a New Generation of Comfort
2
-
Components View
3
- Furnace Components
3
-
Safety Considerations
4
-
Before Starting Your Furnace
4
-
Starting and Shutting down Your Furnace
5
-
Steps for Starting Your Furnace
5
-
Shutting down Your Furnace
7
-
- Performing Routine Maintenance
7
- Filtering out Trouble
7
-
-
Combustion Area and Vent System
10
-
Heading South for the Winter
11
-
- Troubleshooting
13
-
A Check- -Up Checklist
13
- Before You Request a Service Call
13
- Installation Data
14
Advertisem*nt
Advertisem*nt
Related Products
- Bryant PLUS 90X 353AAV
- Bryant PLUS 95S 355CAV
- Bryant PO8UAA
- Bryant PG96VTA
- Bryant PURON PLUS 598B
- Bryant ZONE PERFECT PLUS A96447
- Bryant DURAPAC PLUS 581B
- Bryant DURAPAC PLUS SERIES 542J
- Bryant DURAPAC PLUS 581A
- Bryant DuraPac Plus 549B
Bryant Categories
Furnace Air Conditioner Heat Pump Thermostat Fan
More Bryant Manuals